If HS is set as 38.2 and LS is set as 37.4, then the desire temperature (incubating temperature adjustment) can only be changed from 38.2 to 37.4, so the minimum temperature shall be limited to 37.2 even if the “-“ is kept on pressing. High and normal value (indicating + value) if the incubator reading is too low.ĥ- Temperature Upper and lower limit set (HS and LS) HS - (High Set) and LS - (Low Set) set the limit of the setting range of the desired temperature setting (incubating temperature adjustment) Note that the adjustment is the difference between the thermometer readingsĪnd should be adjusted with “- “ if the temperature reading of the incubator is to (CA)Ĥ-2- Press and hold “temperature setting” for 3 sec.Ĥ-3- Push “+” or “-“ until code “CA” appears in the temperature screen.Ĥ-5- Push “+” or “-“ to adjust to the correct measurement. The reading given by the thermometer can be adjusted if you find that the temperature reading is incorrect using a calibrated thermometer.Ĥ-1- Calibrating the temperature sensor measurement. (AL)ģ-1-1- Press and hold “temperature setting” for 3 sec.ģ-1-2- Push “+” or “-“ until code “AL” appears in the temperature screen.ģ-1-4- Push “+” or “-“ to adjust to your desired lower alarm setting.ģ-2- Higher temperature alarmparameter setting (AH)ģ-2-1- Press and hold “temperature setting” for 3 sec.ģ-2-2- Push “+” or “-“ until code “AH” appears in the temperature screen.ģ-2-4- Push “+” or “-“ to adjust to your desired higher alarm setting.Ĥ- Calibrating temperature sensor reading (CA) The thermometer correct reading is set at 0oC. This is sufficient and you do not need to make any changes to these settings.ģ-1- Low temperature alarmparameter setting. I recommend you set the temperature at 37.6oC.ģ- Temperature alarm parameter settings (AL and AH) The temperature alarm is factory set to sound at 1oC over or below the set temperature. These incubators are factory set at 38oC, I found the chicks hatch at day 19 to 20 meaning the temperature being to high. 1- Testing your incubator for the first time: 1-1- Connect the egg turner plug to the control plug.ġ-2- Connect the provided power wire to your power source.ġ-5- You will hear an alarm sounding due to low temperature/humidity, it’s normal, don’t worry.ġ-6- Press any of the green buttons to cancel the alarm.ġ-7- Operate the incubator and filling the water hole you will notice the humidity reading increase.Ģ- Setting the temperature 2-1- Push “temperature setting/Humidity Setting” once.Ģ-2- Push “+” or “-“ to select the desired temperature.Ģ-3- Push “temperature setting/Humidity Setting” once more to exit.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |